Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Arch Pathol Lab Med ; 143(6): 722-731, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30457897

RESUMO

CONTEXT.­: Clinical responses to anti-programmed death receptor-1 and anti-programmed death ligand-1 (PD-L1) agents are generally improved in patients with high PD-L1 expression compared with those with low/negative expression across several tumor types, including urothelial carcinoma. OBJECTIVE.­: To validate a PD-L1 immunohistochemical diagnostic test in urothelial carcinoma patients treated with the anti-PD-L1 monoclonal antibody durvalumab. DESIGN.­: The Ventana PD-L1 (SP263) assay was validated for intended use in urothelial carcinoma formalin-fixed, paraffin-embedded samples in studies addressing sensitivity, specificity, robustness, and precision, and implemented in study CD-ON-MEDI4736-1108 (NCT01693562). Efficacy was analyzed in patients classified according to prespecified PD-L1 expression cutoffs: PD-L1 high (if >1% of the tumor area contained tumor-associated immune cells, ≥25% of tumor cells or ≥25% of immune cells stained for PD-L1; if ≤1% of the tumor area contained immune cells, ≥25% of tumor cells or 100% of immune cells stained for PD-L1) and PD-L1 low/negative (did not meet criteria for PD-L1 high). RESULTS.­: The assay met all predefined acceptance criteria for sensitivity, specificity, and precision. Interreader and intrareader precision overall agreement were 93.0% and 92.4%, respectively. For intraday reproducibility and interday precision, overall agreement was 99.2% and 100%, respectively. Interlaboratory overall agreement was 92.6%. In study CD-ON-MEDI4736-1108, durvalumab demonstrated clinical activity and durable responses in both PD-L1-high and PD-L1-low/negative subgroups, although objective response rates tended to be higher in the PD-L1-high subgroup than in the PD-L1-low/negative subgroup. CONCLUSIONS.­: Determination of PD-L1 expression in urothelial carcinoma patients using the Ventana PD-L1 (SP263) assay was precise, highly reproducible, and clinically relevant.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Antineoplásicos Imunológicos/uso terapêutico , Antígeno B7-H1/análise , Carcinoma de Células de Transição/tratamento farmacológico , Imuno-Histoquímica/métodos , Neoplasias da Bexiga Urinária/tratamento farmacológico , Adulto , Algoritmos , Carcinoma de Células de Transição/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Neoplasias da Bexiga Urinária/metabolismo
2.
J Thorac Oncol ; 12(2): 208-222, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27913228

RESUMO

INTRODUCTION: The Blueprint Programmed Death Ligand 1 (PD-L1) Immunohistochemistry (IHC) Assay Comparison Project is an industrial-academic collaborative partnership to provide information on the analytical and clinical comparability of four PD-L1 IHC assays used in clinical trials. METHODS: A total of 39 NSCLC tumors were stained with four PD-L1 IHC assays (22C3, 28-8, SP142, and SP263), as used in the clinical trials. Three experts in interpreting their respective assays independently evaluated the percentages of tumor and immune cells staining positive at any intensity. Clinical diagnostic performance was assessed through comparisons of patient classification above and below a selected expression cutoff and by agreement using various combinations of assays and cutoffs. RESULTS: Analytical comparison demonstrated that the percentage of PD-L1-stained tumor cells was comparable when the 22C3, 28-8, and SP263 assays were used, whereas the SP142 assay exhibited fewer stained tumor cells overall. The variability of immune cell staining across the four assays appears to be higher than for tumor cell staining. Of the 38 cases, 19 (50.0%) were classified above and five (13%) were classified below the selected cutoffs of all assays. For 14 of the 38 cases (37%), a different PD-L1 classification would be made depending on which assay/scoring system was used. CONCLUSIONS: The Blueprint PD-L1 IHC Assay Comparison Project revealed that three of the four assays were closely aligned on tumor cell staining whereas the fourth showed consistently fewer tumor cells stained. All of the assays demonstrated immune cell staining, but with greater variability than with tumor cell staining. By comparing assays and cutoffs, the study indicated that despite similar analytical performance of PD-L1 expression for three assays, interchanging assays and cutoffs would lead to "misclassification" of PD-L1 status for some patients. More data are required to inform on the use of alternative staining assays upon which to read different specific therapy-related PD-L1 cutoffs.


Assuntos
Antígeno B7-H1/metabolismo , Bioensaio/métodos , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Imuno-Histoquímica/métodos , Neoplasias Pulmonares/metabolismo , Anticorpos Monoclonais/imunologia , Anticorpos Monoclonais/metabolismo , Antígeno B7-H1/imunologia , Biomarcadores Tumorais/metabolismo , Carcinoma Pulmonar de Células não Pequenas/patologia , Estudos de Coortes , Humanos , Neoplasias Pulmonares/patologia , Prognóstico
3.
Diagn Pathol ; 11(1): 95, 2016 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-27717372

RESUMO

BACKGROUND: A high-quality programmed cell-death ligand 1 (PD-L1) diagnostic assay may help predict which patients are more likely to respond to anti-programmed cell death-1 (PD-1)/PD-L1 antibody-based cancer therapy. Here we describe a PD-L1 immunohistochemical (IHC) staining protocol developed by Ventana Medical Systems Inc. and key analytical parameters of its use in formalin-fixed, paraffin-embedded (FFPE) samples of non-small cell lung cancer (NSCLC) and head and neck squamous cell carcinoma (HNSCC). METHODS: An anti-human PD-L1 rabbit monoclonal antibody (SP263) was optimized for use with the VENTANA OptiView DAB IHC Detection Kit on the automated VENTANA BenchMark ULTRA platform. The VENTANA PD-L1 (SP263) Assay was validated for use with FFPE NSCLC and HNSCC tissue samples in a series of studies addressing sensitivity, specificity, robustness, and precision. Samples from a subset of 181 patients from a Phase 1/2 study of durvalumab (NCT01693562) were analyzed to determine the optimal PD-L1 staining cut-off for enriching the probability of responses to treatment. The scoring algorithm was defined using statistical analysis of clinical response data from this clinical trial and PD-L1 staining parameters in HNSCC and NSCLC tissue. Inter-reader agreement was established by three pathologists who evaluated 81 NSCLC and 100 HNSCC samples across the range of PD-L1 expression levels. RESULTS: The VENTANA PD-L1 (SP263) Assay met all pre-defined acceptance criteria. For both cancer types, a cut-off of 25 % of tumor cells with PD-L1 membrane staining of any intensity best discriminated responders from nonresponders. Samples with staining above this value were deemed to have high PD-L1 expression, and those with staining below it were deemed to have low or no PD-L1 expression. Inter-reader agreement on PD-L1 status was 97 and 92 % for NSCLC and HNSCC, respectively. CONCLUSIONS: These results highlight the robustness and reproducibility of the VENTANA PD-L1 (SP263) Assay and support its suitability for use in the evaluation of NSCLC and HNSCC FFPE tumor samples using the devised ≥25 % tumor cell staining cut-off in a clinical setting. The clinical utility of the PD-L1 diagnostic assay as a predictive biomarker will be further validated in ongoing durvalumab studies. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01693562.


Assuntos
Antígeno B7-H1/análise , Biomarcadores Tumorais/análise , Carcinoma Pulmonar de Células não Pequenas/química , Carcinoma de Células Escamosas/química , Neoplasias de Cabeça e Pescoço/química , Imuno-Histoquímica , Neoplasias Pulmonares/química , Algoritmos , Anticorpos Monoclonais/uso terapêutico , Antineoplásicos/uso terapêutico , Área Sob a Curva , Antígeno B7-H1/antagonistas & inibidores , Antígeno B7-H1/imunologia , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/imunologia , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/imunologia , Carcinoma de Células Escamosas/patologia , Linhagem Celular Tumoral , Fixadores , Formaldeído , Células HEK293 , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/imunologia , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Ensaio de Proficiência Laboratorial , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/imunologia , Neoplasias Pulmonares/patologia , Variações Dependentes do Observador , Inclusão em Parafina , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Carcinoma de Células Escamosas de Cabeça e Pescoço , Fixação de Tecidos/métodos , Transfecção
4.
Diagn Pathol ; 11(1): 44, 2016 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-27189072

RESUMO

BACKGROUND: Programmed Death Ligand 1 (PD-L1) is an immune modulating protein expressed on the surface of various inflammatory cells, including T Cells, B Cells, dendritic cells, and macrophages. PD-L1 represents an important diagnostic target; expression of PD-L1 on the surface of tumor cells, or within tumor-associated immune cells, is an important predictor of likely response to targeted therapies. In this study, we describe the optimization of immunohistochemistry (IHC) assays using two PD-L1 antibodies (SP263 and E1L3N) and compare the performance of the optimized assays. METHODS: Fully automated immunohistochemical assays were optimized for the VENTANA PD-L1 (SP263) Rabbit Monoclonal Antibody and the PD-L1 (E1L3N®) XP® Rabbit mAb using instruments and detection chemistries from Ventana Medical Systems, Inc. ("SP263 assay" and "E1L3N assay," respectively). Tissue microarrays (TMAs) containing formalin fixed paraffin embedded (FFPE) non-small cell lung cancer (NSCLC) cases were used for the optimization and comparison staining. H scores were used for membrane scoring whereas percent positivity was used for tumor-associated immune cell scoring. RESULTS: One-hundred NSCLC TMA case cores each stained with the SP263 and E1L3N assays were evaluated by two pathologists in a blinded study. Analysis of these specimens showed that the SP263 assay was more sensitive and had a wider dynamic range than the E1L3N assay. For sensitivity, many cases were found to be negative for membrane staining with the E1L3N assay, but had measurable staining with the SP263 assay. Dynamic range was demonstrated by the SP263 assay having well-distributed H scores while the E1L3N assay had a significantly higher proportion of cases clustered in the lowest H score bins. For tumor-associated immune cell staining, the two assays identified similar amounts of cells staining in each case, but the SP263 assay gave overall darker staining. CONCLUSION: Since PD-L1 status is important for targeted therapies, having a specific and accurate diagnostic test is crucial for identifying patients who could benefit from these treatments. Due to its staining intensity, scoring range, and pathologist preference, the SP263 IHC assay has been deemed superior to the E1L3N IHC assay. Future clinical utility remains to be determined.


Assuntos
Anticorpos Monoclonais , Antígeno B7-H1/metabolismo , Biomarcadores Tumorais/metabolismo , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Neoplasias Pulmonares/metabolismo , Animais , Anticorpos Monoclonais/imunologia , Antígeno B7-H1/genética , Antígeno B7-H1/imunologia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Humanos , Imuno-Histoquímica , Neoplasias Pulmonares/diagnóstico , Coelhos , Coloração e Rotulagem , Análise Serial de Tecidos
5.
BMC Cancer ; 8: 91, 2008 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-18397527

RESUMO

BACKGROUND: Recent advances in genomics, proteomics, and the increasing demands for biomarker validation studies have catalyzed changes in the landscape of cancer research, fueling the development of tissue banks for translational research. A result of this transformation is the need for sufficient quantities of clinically annotated and well-characterized biospecimens to support the growing needs of the cancer research community. Clinical annotation allows samples to be better matched to the research question at hand and ensures that experimental results are better understood and can be verified. To facilitate and standardize such annotation in bio-repositories, we have combined three accepted and complementary sets of data standards: the College of American Pathologists (CAP) Cancer Checklists, the protocols recommended by the Association of Directors of Anatomic and Surgical Pathology (ADASP) for pathology data, and the North American Association of Central Cancer Registry (NAACCR) elements for epidemiology, therapy and follow-up data. Combining these approaches creates a set of International Standards Organization (ISO) - compliant Common Data Elements (CDEs) for the mesothelioma tissue banking initiative supported by the National Institute for Occupational Safety and Health (NIOSH) of the Center for Disease Control and Prevention (CDC). METHODS: The purpose of the project is to develop a core set of data elements for annotating mesothelioma specimens, following standards established by the CAP checklist, ADASP cancer protocols, and the NAACCR elements. We have associated these elements with modeling architecture to enhance both syntactic and semantic interoperability. The system has a Java-based multi-tiered architecture based on Unified Modeling Language (UML). RESULTS: Common Data Elements were developed using controlled vocabulary, ontology and semantic modeling methodology. The CDEs for each case are of different types: demographic, epidemiologic data, clinical history, pathology data including block level annotation, and follow-up data including treatment, recurrence and vital status. The end result of such an effort would eventually provide an increased sample set to the researchers, and makes the system interoperable between institutions. CONCLUSION: The CAP, ADASP and the NAACCR elements represent widely established data elements that are utilized in many cancer centers. Herein, we have shown these representations can be combined and formalized to create a core set of annotations for banked mesothelioma specimens. Because these data elements are collected as part of the normal workflow of a medical center, data sets developed on the basis of these elements can be easily implemented and maintained.


Assuntos
Aplicações da Informática Médica , Mesotelioma , Neoplasias Pleurais , Bancos de Tecidos , Biologia Computacional , Bases de Dados como Assunto , Humanos , Software , Integração de Sistemas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...